resDNASEQ Human Residual DNA Fragment Analysis Detection Kit

$3,699.00

Note: Price not include shipment & duty, contact us to get full quote.

The resDNASEQ™ Human Residual DNA Fragment Analysis Kit (qPCR) use TaqManTM quantitative PCR to perform rapid, specifc quantitation of femtogram levels of residual host-cell or plasmid DNA. This kit employs qPCR with TaqMan®-based fluorescent hydrolysis probes for highly specific and sensitive detection of DNA fragments at four defined amplicon sizes: 66 bp, 150 bp, 200 bp, and 528 bp. Notably, the qPCR amplification efficiency approaches 100%, even for longer DNA fragments, ensuring reliable detection and quantitation of residual DNA throughout bioprocess development and quality control. The assay is accurate and reliable across a broad range of sample types, from in-process samples to final product.

Catalog number:

Cat. No. D24011210

Qty:

100 Reactions

Description

This kit employs qPCR with TaqMan®-based fluorescent hydrolysis probes for highly specific and sensitive detection of DNA fragments at four defined amplicon sizes: 66 bp, 150 bp, 200 bp, and 528 bp. To generate the standard curve used to quantitate the DNA in test samples, Each Fragment assay requires five dilutions. DNA control from Human cells (Human DNA Control) is included in the kit. In addition, the kits use an internal positive control (IPC) to evaluate the performance of each PCR reaction. UDG enzyme is used in this kit to avoid the contamination of amplification products.

Features of the resDNASEQ Human Residual DNA Fragment Analysis Detection Kit include:

 

Simpler and Rapid
  • Easy to operate:Only 30 minutes are required for sample preparation.
  • Only one Reagent for qPCR;
  • Easy to store.
  • Only 3 hours will be needed for the whole test.
Accurate
  • Simultaneous detection revealed fragments of 66 bp, 150 bp, 200 bp, and 528 bp.
  • Excellent amplification efficiency was observed, with the 500+ bp fragment showing nearly 100% efficiency
  • Excellent specificity, accuracy, stability, precision and after-sales service.
  • Highly sensitive quantitation using proven TaqMan™ real-time qPCR technology. Limit of Detection (LOD): 30 fg/μL.
  • The recovery rate of different concentration samples in the linear range is between 70% and 130%.
Kit Performance

 

Fig 1. Amplification efficiencies all four fragments ranged from 99% to 101%.

Fig 2. The limit of quantification (LOQ) for each of the four fragments was determined to be 30 fg/μL.

Fig 3. the Recovery the Recovery were between 80% and 120% was between 80% and 120%.

 